Fuel and solvents recovery vacuum cleaner systems:
ATEX Category 2 Explosion proof vacuum cleaner systems for ATEX Zone 1 (Gas) and
ATEX Zone 21 (Dust) (where indicated)
|
|
Electric Models
Electrically Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/flammable liquids.
0081
II 2 G/D Ex d IIB T4 Ex tD A21
IP6X - T135oC
LCIE 03 ATEX 6295
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- Three-Phase motor
- Fuel and solvent recovery
- Equipped with a Middle Ring with Activated Carbon (MRAC) for for adsorption of toxic/nuisance fumes and vapors
- Carbon cartridge contains 18 lbs (8 kg) of activated carbon pellets. Different types or carbon are available
- Recovery capacity of 15 gallons (57 liters) - liquid and 17 gallons (64 liters) - dry
- Equipped with a heavy duty powder coated hydrolic cart for easy emptying of recovered materials
- Group E Motor (Metal Dust) available
- Other motor performances available
Electrically Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
0081
II 2 G/D Ex d IIA T4 Ex tD A21
IP65 – T 120°C
LCIE 03 ATEX 6297
0081
II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- Available with an optional Activated Carbon Cartridge for the adsorption of toxic/nuisance fumes and vapors
- Designed for aircraft de-fueling and de-puddling
- Single phase explosion proof/dust ignition proof motor
- For wet and dry recovery
- All stainless steel SAE 304 construction (except cart) with red and yellow bands
- Recovery capacity of 12.5 - 45 gallons (47.5 - 171 liters) - wet and 10 - 40 gallons (38 - 152 liters) - dry
- Equipped with an SD* 4-wheel tilting cart for easy emptying of recovered materials
SD* Static Dissipative
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
- Less than 10 Ohms of resistivity
- *Cleanroom compatible. Can be used in the pharmaceutical industry
- Designed for the adsorption of toxic/nuisance vapors, fumes and odors
- For wet & dry recovery
- All stainless steel SAE 304
- Drum system contains 55 lbs (25 kilos) of activated carbon pellets
- Based on an SD* 4-wheel dolly for easy maneuverability. Cart has SD* conductive wheels
- Includes a static dissipating, fuel resistant, connection hose
Electrically Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
0081
II 2 G/D Ex d IIA T4 Ex tD A21
IP65 – T 120°C
LCIE 03 ATEX 6297
0081
II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- Available with an optional Activated Carbon Cartridge for the adsorption of toxic/nuisance fumes and vapors
- Designed for aircraft de-fueling and de-puddling
- Single phase explosion proof/dust ignition proof motor
- For wet and dry recovery
- All stainless steel SAE 304 construction (except cart) with red and yellow bands
- Recovery capacity of 45 gallons (171 liters) - wet and 40 gallons (152 liters) - dry
- Equipped with an SD* 4-wheel tilting cart for easy emptying of recovered materials. Also equipped with a Dead Man Brake to avoid unit movement while on duty
SD* Static Dissipative
Pneumatic (Air) Models
Pneumatically (Air) Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
II 2 G/D c IIC T6 (85oC)
LCIE 03 ATEX 6310
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- Coalescing Filter Element (CFE) for moisture removal
- HEPA Filter - Optional with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Pneumatically (air) operated
- Fuel, oil and Solvent recovery
- Activated Carbon Drum System acts as an Adsorption Fume and Vapor recovery unit
- Capacity of 55 lbs. (25 kilos) of activated carbon pellets for the adsorption of contaminated fumes and vapors
- Recovery capacity of 15 gallons (57 liters) - wet and 17 gallons (64 liters) - dry
- Equipped with a heavy duty powder coated Hydraulic Cart for easy emptying of recovered materials.
Pneumatically (Air) Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
II 2 G/D c IIC T6 (85oC)
LCIE 03 ATEX 6310
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- Available with an optional Activated Carbon Cartridge for the adsorption of toxic/nuisance fumes and vapors
- Designed for aircraft de-fueling and de-puddling
- Pneumatically (air) operated
- For wet & dry recovery
- All stainless steel SAE 304 construction (except cart) with red and yellow bands
- Recovery capacity of 12.5 - 45 gallons (47.5 - 171 liters) - wet and 10 - 40 gallons (38 - 152 liters) - dry
- Equipped with an SD* 4-wheel tilting cart for easy emptying of recovered materials
SD* Static Dissipative
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
- Less than 10 Ohms of resistivity
- *Cleanroom compatible. Can be used in the pharmaceutical industry
- Designed for the adsorption of toxic/nuisance vapors, fumes and odors
- For wet & dry recovery
- All stainless steel SAE 304
- Drum system contains 55 lbs (25 kilos) of activated carbon pellets
- Based on an SD* 4-wheel dolly for easy maneuverability. Cart has SD* conductive wheels
- Includes a static dissipating, fuel resistant, connection hose
Pneumatically (Air) Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
II 2 G/D c IIC T6 (85oC)
LCIE 03 ATEX 6310
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- Available with an optional Activated Carbon Cartridge for the adsorption of toxic/nuisance fumes and vapors
- Designed for aircraft de-fueling and de-puddling
- Pneumatically (air) operated
- For wet and dry recovery
- All stainless steel SAE 304 construction (except cart) with red and yellow bands
- Recovery capacity of 45 gallons (171 liters) - wet and 40 gallons (152 liters) - dry
- Equipped with an SD* 4-wheel tilting cart for easy emptying of recovered materials. Also equipped with a Dead Man Brake to avoid unit movement while on duty
SD* Static Dissipative
Pneumatically (Air) Operated
Certifications

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.
II 2 G/D c IIC T6 (85oC)
LCIE 03 ATEX 6310
- Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
- Less than 10 Ohms of resistivity
- Coalescing Filter Element (CFE) for moisture removal
- HEPA Filter - Optional with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
- Pneumatically (air) operated
- Fuel, oil and Solvent recovery. Ideal for the recovery of Hydrazine
- Recovery capacity of 15 gallons (57 liters) - wet
- Equipped with a heavy duty powder coated Hydraulic Cart for easy emptying of recovered materials.
Note:
- HEPA Filters - efficiency of 99.995% on 0.3 microns - Tested IEST RP-CC001.3 - H14 as per MPPS method EN 1822.
- ULPA Filters - efficiency of 99.999% on 0.3 microns - Filtration efficiency of 99.9995% on 0.18 microns - Tested IEST RP-CC001.3 - U15 as per MPPS method EN 1822
- Please be advised that all Tiger-Vac HEPA/ULPA Filters are Aerosol tested when assembled, either upstream or downstream, inside of the vacuum cleaners.
- All Tiger-Vac HEPA/ULPA Filters are assembled mechanically with 3 bolts and include a specially designed memory gasket in order to prevent any leaks during the life span of the gasket thus insuring the health and safety of the end user.